{"id":1296,"date":"2017-12-06T22:57:49","date_gmt":"2017-12-06T21:57:49","guid":{"rendered":"https:\/\/www.italmanometri.com\/?page_id=1296"},"modified":"2017-12-20T11:59:17","modified_gmt":"2017-12-20T10:59:17","slug":"bourdon-tube-pressure-gauges","status":"publish","type":"page","link":"https:\/\/www.italmanometri.com\/en\/bourdon-tube-pressure-gauges\/","title":{"rendered":"BOURDON TUBE PRESSURE GAUGES"},"content":{"rendered":"<div id=\"pl-12\" class=\"panel-layout\">\n<div id=\"pg-12-0\" class=\"panel-grid panel-no-style\">\n<div id=\"pgc-12-0-0\" class=\"panel-grid-cell\" data-weight=\"1\">\n<div id=\"panel-12-0-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\" data-index=\"0\" data-style=\"{&quot;background_display&quot;:&quot;tile&quot;}\">\n<div class=\"so-widget-sow-editor so-widget-sow-editor-base\">\n<div class=\"siteorigin-widget-tinymce textwidget\">\n<p class=\"testo\"><strong>INSTRUCTION FOR MOUNTING AND USE OF BOURDON TUBE PRESSURE GAUGES<\/strong><\/p>\n<p class=\"testo\"><strong>Overpressure allowed on standard pressure gauges.<\/strong><br \/>\n&#8211; Static: 3\/4 of pressure gauge value at the end of range.<br \/>\n&#8211; Fluctuating: 2\/3 of pressure gauge value at the end of range.<br \/>\n&#8211; Short time: value of pressure gauge range.<br \/>\n&#8211; Warning: overpressure are not admitted over the 10-15% of range.<\/p>\n<p class=\"testo\"><strong>Warning<\/strong>!<br \/>\nDo not use the standard pressure gauges with oxygen, corrosive fluids or gas not compatible with copper and its alloys, in this case please contact<br \/>\nItalmanometri Tecnical Service. There are no particular dangers of reaction with other substances under normal operating conditions.<br \/>\nMay react with strong oxidizing agents. Nitric acid\/sulphuric acid, phosphorus oxide, Peroxide, hydrogen peroxide (H2O2), halogens.<\/p>\n<p class=\"testo\"><strong>Repair-maintenance.<\/strong><br \/>\n&#8211; It is better to change than repair a standard pressure gauge.<br \/>\n&#8211; By high quality pressure gauges repair will not be more expensive than purchase a new gauge.<\/p>\n<p class=\"testo\"><strong>Storage<\/strong>.<br \/>\nPressure gauges must be storage observing the following rules:<br \/>\n&#8211; Don\u2019t lay more than 3 boxes of pressure gauges.<br \/>\n&#8211; Keep away from dust, humidity, high and low temperature.<br \/>\n&#8211; Liquid filled pressure gauge must be storage without light.<br \/>\n&#8211; Don\u2019t storage liquid filled pressure gauges up side down.<\/p>\n<p class=\"testo\"><strong>Storage time.<\/strong><br \/>\nIn case of the pressure gauges are between 15\/30 degree and storage like the indication written before:<br \/>\n&#8211; dry pressure gauges: 6 year &#8211; liquid filled pressure gauges: 2 years.<\/p>\n<p class=\"testo\"><strong>Assembly system of standard pressure gauges<\/strong><br \/>\nA pressure gauge is calibrated in a vertical position, however and is not a defect, the pointer may be out of zero if the instrument is horizontal, chiefly for low pressure ranges (fig. 1a and 1 b).<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div id=\"pg-12-1\" class=\"panel-grid panel-no-style\" data-style=\"{&quot;background_display&quot;:&quot;tile&quot;,&quot;cell_alignment&quot;:&quot;flex-start&quot;}\">\n<div id=\"pgc-12-1-0\" class=\"panel-grid-cell\" data-weight=\"0.5\">\n<div id=\"panel-12-1-0-0\" class=\"so-panel widget widget_sow-image panel-first-child panel-last-child\" data-index=\"1\" data-style=\"{&quot;background_display&quot;:&quot;tile&quot;}\">\n<div class=\"so-widget-sow-image so-widget-sow-image-default-813df796d9b1\">\n<div class=\"sow-image-container\"><img loading=\"lazy\" decoding=\"async\" class=\"so-widget-image\" src=\"https:\/\/www.italmanometri.com\/wp-content\/uploads\/norme1a.jpg\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" srcset=\"https:\/\/www.italmanometri.com\/wp-content\/uploads\/norme1a.jpg 400w, https:\/\/www.italmanometri.com\/wp-content\/uploads\/norme1a-300x166.jpg 300w\" width=\"400\" height=\"221\" \/><\/div>\n<\/div>\n<\/div>\n<\/div>\n<div id=\"pgc-12-1-1\" class=\"panel-grid-cell\" data-weight=\"0.5\">\n<div id=\"panel-12-1-1-0\" class=\"so-panel widget widget_sow-image panel-first-child panel-last-child\" data-index=\"2\" data-style=\"{&quot;background_display&quot;:&quot;tile&quot;}\">\n<div class=\"so-widget-sow-image so-widget-sow-image-default-813df796d9b1\">\n<div class=\"sow-image-container\"><img loading=\"lazy\" decoding=\"async\" class=\"so-widget-image\" src=\"https:\/\/www.italmanometri.com\/wp-content\/uploads\/norme1b.jpg\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" srcset=\"https:\/\/www.italmanometri.com\/wp-content\/uploads\/norme1b.jpg 400w, https:\/\/www.italmanometri.com\/wp-content\/uploads\/norme1b-300x158.jpg 300w\" width=\"400\" height=\"211\" \/><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div id=\"pg-12-2\" class=\"panel-grid panel-no-style\" data-style=\"{&quot;background_display&quot;:&quot;tile&quot;,&quot;cell_alignment&quot;:&quot;flex-start&quot;}\">\n<div id=\"pgc-12-2-0\" class=\"panel-grid-cell\" data-weight=\"1\">\n<div id=\"panel-12-2-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child\" data-index=\"3\" data-style=\"{&quot;background_display&quot;:&quot;tile&quot;}\">\n<div class=\"so-widget-sow-editor so-widget-sow-editor-base\">\n<div class=\"siteorigin-widget-tinymce textwidget\">\n<p>Never install the pressure gauge by turning the case but mount it with a wrench by means of the hexagon or flats provided on the sochet (fig. 2)<\/p>\n<p>By BSP parallel standard threads place a gasket between the end of the thread and around the spigot. By BSPT and NPT conical standard thread<br \/>\nthightness is achieved metal on metal without any gasket. However a teflon tape woundaround the thread provides a better tightness and makes the<br \/>\nscrewing easier. (fig. 3) Vibrations of the pressure gauges must be avoided to prevent excessive wear of the mechanism. It would be better to set the gauge on a rigid support on wich the vibrations of the pipe have no influence. (fig. 4)<br \/>\nPressure pulsation: must use liquid filled pressure gauges, fluid separator or coil tube. (fig. 5)<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-126\" src=\"https:\/\/www.italmanometri.com\/wp-content\/uploads\/norme.jpg\" alt=\"\" width=\"1051\" height=\"200\" srcset=\"https:\/\/www.italmanometri.com\/wp-content\/uploads\/norme.jpg 1051w, https:\/\/www.italmanometri.com\/wp-content\/uploads\/norme-300x57.jpg 300w, https:\/\/www.italmanometri.com\/wp-content\/uploads\/norme-768x146.jpg 768w, https:\/\/www.italmanometri.com\/wp-content\/uploads\/norme-1024x195.jpg 1024w\" sizes=\"auto, (max-width: 1051px) 100vw, 1051px\" \/><\/p>\n<\/div>\n<\/div>\n<\/div>\n<div id=\"panel-12-2-0-1\" class=\"so-panel widget widget_black-studio-tinymce widget_black_studio_tinymce\" data-index=\"4\" data-style=\"{&quot;background_display&quot;:&quot;tile&quot;}\">\n<h3 class=\"widget-title\"><\/h3>\n<div class=\"textwidget\"><\/div>\n<\/div>\n<div id=\"panel-12-2-0-3\" class=\"so-panel widget widget_black-studio-tinymce widget_black_studio_tinymce panel-last-child\" data-index=\"6\" data-style=\"{&quot;background_display&quot;:&quot;tile&quot;}\">\n<div class=\"textwidget\">\n<p>&nbsp;<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>INSTRUCTION FOR MOUNTING AND USE OF BOURDON TUBE PRESSURE GAUGES Overpressure allowed on standard pressure gauges. &#8211; Static: 3\/4 of pressure gauge value at the end of range. &#8211; Fluctuating: 2\/3 of pressure gauge value at the end of range. &#8211; Short time: value of pressure gauge range. &#8211; Warning: overpressure are not admitted over [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"parent":0,"menu_order":22,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":"","_links_to":"","_links_to_target":""},"class_list":{"0":"post-1296","1":"page","2":"type-page","3":"status-publish","5":"entry","6":"gs-1","7":"gs-odd","8":"gs-even","9":"gs-featured-content-entry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>BOURDON TUBE PRESSURE GAUGES - Italmanometri<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.italmanometri.com\/en\/bourdon-tube-pressure-gauges\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"BOURDON TUBE PRESSURE GAUGES - Italmanometri\" \/>\n<meta property=\"og:description\" content=\"INSTRUCTION FOR MOUNTING AND USE OF BOURDON TUBE PRESSURE GAUGES Overpressure allowed on standard pressure gauges. &#8211; Static: 3\/4 of pressure gauge value at the end of range. &#8211; Fluctuating: 2\/3 of pressure gauge value at the end of range. &#8211; Short time: value of pressure gauge range. &#8211; Warning: overpressure are not admitted over [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.italmanometri.com\/en\/bourdon-tube-pressure-gauges\/\" \/>\n<meta property=\"og:site_name\" content=\"Italmanometri\" \/>\n<meta property=\"article:modified_time\" content=\"2017-12-20T10:59:17+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.italmanometri.com\/wp-content\/uploads\/norme1a.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.italmanometri.com\\\/en\\\/bourdon-tube-pressure-gauges\\\/\",\"url\":\"https:\\\/\\\/www.italmanometri.com\\\/en\\\/bourdon-tube-pressure-gauges\\\/\",\"name\":\"BOURDON TUBE PRESSURE GAUGES - Italmanometri\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.italmanometri.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.italmanometri.com\\\/en\\\/bourdon-tube-pressure-gauges\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.italmanometri.com\\\/en\\\/bourdon-tube-pressure-gauges\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.italmanometri.com\\\/wp-content\\\/uploads\\\/norme1a.jpg\",\"datePublished\":\"2017-12-06T21:57:49+00:00\",\"dateModified\":\"2017-12-20T10:59:17+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.italmanometri.com\\\/en\\\/bourdon-tube-pressure-gauges\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.italmanometri.com\\\/en\\\/bourdon-tube-pressure-gauges\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.italmanometri.com\\\/en\\\/bourdon-tube-pressure-gauges\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.italmanometri.com\\\/wp-content\\\/uploads\\\/norme1a.jpg\",\"contentUrl\":\"https:\\\/\\\/www.italmanometri.com\\\/wp-content\\\/uploads\\\/norme1a.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.italmanometri.com\\\/en\\\/bourdon-tube-pressure-gauges\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.italmanometri.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"BOURDON TUBE PRESSURE GAUGES\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.italmanometri.com\\\/#website\",\"url\":\"https:\\\/\\\/www.italmanometri.com\\\/\",\"name\":\"Italmanometri\",\"description\":\"Manometri, termometri, trasduttori e strumentazione Made in Italy\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.italmanometri.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.italmanometri.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.italmanometri.com\\\/#organization\",\"name\":\"Italmanometri\",\"url\":\"https:\\\/\\\/www.italmanometri.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.italmanometri.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.italmanometri.com\\\/wp-content\\\/uploads\\\/logo-italmanometri.png\",\"contentUrl\":\"https:\\\/\\\/www.italmanometri.com\\\/wp-content\\\/uploads\\\/logo-italmanometri.png\",\"width\":100,\"height\":100,\"caption\":\"Italmanometri\"},\"image\":{\"@id\":\"https:\\\/\\\/www.italmanometri.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"BOURDON TUBE PRESSURE GAUGES - Italmanometri","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.italmanometri.com\/en\/bourdon-tube-pressure-gauges\/","og_locale":"en_US","og_type":"article","og_title":"BOURDON TUBE PRESSURE GAUGES - Italmanometri","og_description":"INSTRUCTION FOR MOUNTING AND USE OF BOURDON TUBE PRESSURE GAUGES Overpressure allowed on standard pressure gauges. &#8211; Static: 3\/4 of pressure gauge value at the end of range. &#8211; Fluctuating: 2\/3 of pressure gauge value at the end of range. &#8211; Short time: value of pressure gauge range. &#8211; Warning: overpressure are not admitted over [&hellip;]","og_url":"https:\/\/www.italmanometri.com\/en\/bourdon-tube-pressure-gauges\/","og_site_name":"Italmanometri","article_modified_time":"2017-12-20T10:59:17+00:00","og_image":[{"url":"https:\/\/www.italmanometri.com\/wp-content\/uploads\/norme1a.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.italmanometri.com\/en\/bourdon-tube-pressure-gauges\/","url":"https:\/\/www.italmanometri.com\/en\/bourdon-tube-pressure-gauges\/","name":"BOURDON TUBE PRESSURE GAUGES - Italmanometri","isPartOf":{"@id":"https:\/\/www.italmanometri.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.italmanometri.com\/en\/bourdon-tube-pressure-gauges\/#primaryimage"},"image":{"@id":"https:\/\/www.italmanometri.com\/en\/bourdon-tube-pressure-gauges\/#primaryimage"},"thumbnailUrl":"https:\/\/www.italmanometri.com\/wp-content\/uploads\/norme1a.jpg","datePublished":"2017-12-06T21:57:49+00:00","dateModified":"2017-12-20T10:59:17+00:00","breadcrumb":{"@id":"https:\/\/www.italmanometri.com\/en\/bourdon-tube-pressure-gauges\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.italmanometri.com\/en\/bourdon-tube-pressure-gauges\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.italmanometri.com\/en\/bourdon-tube-pressure-gauges\/#primaryimage","url":"https:\/\/www.italmanometri.com\/wp-content\/uploads\/norme1a.jpg","contentUrl":"https:\/\/www.italmanometri.com\/wp-content\/uploads\/norme1a.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/www.italmanometri.com\/en\/bourdon-tube-pressure-gauges\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.italmanometri.com\/"},{"@type":"ListItem","position":2,"name":"BOURDON TUBE PRESSURE GAUGES"}]},{"@type":"WebSite","@id":"https:\/\/www.italmanometri.com\/#website","url":"https:\/\/www.italmanometri.com\/","name":"Italmanometri","description":"Manometri, termometri, trasduttori e strumentazione Made in Italy","publisher":{"@id":"https:\/\/www.italmanometri.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.italmanometri.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.italmanometri.com\/#organization","name":"Italmanometri","url":"https:\/\/www.italmanometri.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.italmanometri.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.italmanometri.com\/wp-content\/uploads\/logo-italmanometri.png","contentUrl":"https:\/\/www.italmanometri.com\/wp-content\/uploads\/logo-italmanometri.png","width":100,"height":100,"caption":"Italmanometri"},"image":{"@id":"https:\/\/www.italmanometri.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.italmanometri.com\/en\/wp-json\/wp\/v2\/pages\/1296","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.italmanometri.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.italmanometri.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.italmanometri.com\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.italmanometri.com\/en\/wp-json\/wp\/v2\/comments?post=1296"}],"version-history":[{"count":1,"href":"https:\/\/www.italmanometri.com\/en\/wp-json\/wp\/v2\/pages\/1296\/revisions"}],"predecessor-version":[{"id":1297,"href":"https:\/\/www.italmanometri.com\/en\/wp-json\/wp\/v2\/pages\/1296\/revisions\/1297"}],"wp:attachment":[{"href":"https:\/\/www.italmanometri.com\/en\/wp-json\/wp\/v2\/media?parent=1296"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}